CLM-2026-000404
Meadow Reference Lab, Clinical Laboratory. Service 2026-01-01 at outpatient hospital (POS 22). Received 2026-02-15.
Member
Resolved through the identity graph
- Member
- Brenda Jimenez
- Member ID
- UHC-35314-08
- Date of birth
- 1946-09-24
- Identity
- Verified4 records, confidence 0.99
- Claim record
- CLMCLM-408733
- Relationship
- Self, Atlanta, GA
Coverage and accumulators
Found by member ID
- Plan
- NAVIGATE-HMO HMO group GRP-2091
- Coverage period
- 2025-01-01 to present
- Deductible
- $1,730.08 of $3,500.0049%
- Out-of-pocket maximum
- $6,848.22 of $14,000.0049%
- Copays
- office $40.00, specialist $40.00, emergency $250.00
- Physical therapy visits
- 15 of 20 used
Provider
Billing and rendering
- Billing provider
- Meadow Reference LabClinical Laboratory · taxonomy 291U00000X
- NPI
- 4223959956
- Network
- In network
- Rendering NPI
- 4223959956
- Location
- Mesa, AZ · TIN 32-8579975
- Authorisation / referral
- PA2025214228 / none
Service lines
UB-04: procedures, modifiers, units, charges and the pricing outcome per line
| Line | Code | Description | Mod. | Units | Dx | Billed | Allowed | Member | Plan | Line status |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 70553 rev 0610 | MRI brain with and without contrast | — | 1 | 1 | $3,299.00 | $1,814.45 | — | — | Review |
| Totals | $3,299.00 | $1,814.45 | — | — | ||||||
- 1. Z00.00 Encounter for general adult medical examination without abnormal findingsprincipal
- Patient account
- PA-224524
- Frequency code
- 1 (original)
- Accident
- No
- DRG
- —
- Admit / discharge
- —
- Landed
- 2026-10-21 13:43
Rules engine
CLAIMS-ADJ v1: 11 checks, 1 needing attention
| Check | Result | Code | Detail |
|---|---|---|---|
| Member identity | Pass | Attached to MBR-000309 (verified, link confidence 0.99). | |
| Eligibility | Pass | Active on 2026-01-01: NAVIGATE-HMO (HMO), effective 2025-01-01. | |
| Timely filing | Pass | Received 45 days after service (limit 90). | |
| Duplicate check | Pass | No matching prior claim in the duplicate window. | |
| Prior authorisation | Pass | Authorisation PA2025214228 on file for 70553. | |
| Provider network | Pass | In-network provider Meadow Reference Lab (4223959956). | |
| Medical necessity | Review | CO50 | 70553 billed with routine diagnosis Z00.00; clinical notes must support necessity. Not medically necessary per payer policy |
| Bundling (NCCI) | Pass | No bundling conflicts. | |
| Benefit limits | Pass | No limited benefit on this claim. | |
| Completeness | Pass | Required documentation present. | |
| High-dollar review | Pass | Within the auto-adjudication ceiling. |
Notes
Provider, system and examiner notes on this claim
- ClinicalProvider: Meadow Reference Lab2026-01-01 15:16
Follow-up for encounter for general adult medical examination without abnormal findings. Plan discussed, medications reconciled. Routine screening visit; no acute findings, no red-flag symptoms documented.
- SystemSystem: Claims system2026-02-15 03:49
Clinical edit: advanced imaging billed with a routine examination diagnosis. Sent to nurse review for medical necessity.
- AdministrativeExaminer: M. Alvarez (Claims Examiner I)2026-02-15 16:13
Called the provider office; awaiting documentation.
Attachments
Documents received with the claim
- Prior auth letterPA2025214228_approval.pdf2 pages
Utilisation management approval letter for 70553 (MRI brain with and without contrast), valid 2026-01-01 to 2026-04-01.
- Itemized billitemized_PA-224524.pdf4 pages
Itemised statement totalling $3299.00 across 1 line.
- Medical recordrecords_PA-224524.pdf20 pages
Clinic notes for a routine annual visit; no symptoms documented.
Claim history
Every event on this claim, sealed in the audit chain
- Rules engineReview2026-10-21 13:43Medical necessity: 70553 billed with routine diagnosis Z00.00; clinical notes must support necessity.
Other claims for this member
Same resolved identity
AI recommendation
assist mode · apac.amazon.nova-pro-v1:0
Examiner decision
Record the final decision; pricing and remittance reasons follow from it
Evaluation truth
Hidden label from the synthetic generator; never shown to the model
Routine diagnosis does not support advanced imaging.